9.1.1.

Configuration parameters

9.1.1.1. APN
Format:
Limitations:
Description
9.1.1.2. UN
Format:
Limitations:
Description
9.1.1.3. PW
Format:
Limitations:
Description
9.1.1.4. SERVER
Format:
Limitations:
Description
9.1.1.5. PORT
Format:
Limitations:
Description
9.1.1.6. SMS
Format:
Limitations:
Description
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
APN=apn_name
Data length to 31 characters, can be changed by ATS only
Configures the APN through which data will be sent by GPRS
UN=username
Data length to 31 characters, can be changed by ATS only
Sets the user name for APN
PW=password
Data length to 31 characters, can be changed by ATS only
Sets the password for APN
SERVER=server_address
Data length to 31 characters, can be changed by ATS only
Sets the OSM server address with which the device exchanges data.
Server_address
can
eg.device.mycompany.com domain or IP address, such as 213.216.102.98
PORT=port
A number between 1-65535, can be changed by ATS only
Sets the OSM server address with which the device exchanges data
SMS=phone_number
Data length to 15 characters, can be changed by ATS only
Sets the phone number for sending SMS with the events in the absence of
GPRS communication. If the number is not configured sending SMS
messages will not be available. Phone_number may contain a prefix of the
country.