6.3.1.5. Delay
The parameter is active for delayed and perimeter exit zones only. It defines a time
from the zone disruption was detected after which an alarm is generated.
6.3.1.6. Alarm after time for exit
When selected, the alarm will be generated if the line remains violated when the time
to exit is up.
When deselected, alarm will NOT be generated in above case.
First alarm will be generated after the line is returned and violated again. .
6.3.1.7. Ignore during arming
Zone can be violated during partition arming (e.g. delay circuits shall be set to that
option).
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
69 / 123