EBS CPX220NWB Installation And Programming Manual page 35

Alarm control unit
Table of Contents

Advertisement

XX –
determines the number of output from 01 to 03; entering number 00 will change the
parameters for all outputs in the system,
Y –
number of parameter related to a given output:
 0 – complex function, the initiation of which configures the parameters listed below
as another set of parameters;
1 – type of output (DEC type parameter):
o 0 – not used,
o 1 – signalling alarm,
o 2 – stand-by indicator,
o 3 – power failure,
o 4 – ATS failure – no communication with receiving server.
o 5 – GSM signal jamming indicator
o 6 – chirp on arm/disarm
o 7 – chirp on arm/disarm and signalling alarm
2 – time of output activation in seconds (DEC type parameter); if 0 is set, output will
operate in bi-stable mode.
It is possible to configure the chirp options using following patterns:
chirp signal duration:
a.
b. interval duration between two following chirps:
NOTE: Chirp configuration is common for all outputs
Example:
a) change of a single parameter – operation mode of number 2 output into bi-stable
operation mode:
b) change of 3 output type into triggered by power failure:
c) change of many parameters at the time for output 1 using complex function –
output 1 is to be set as alarm signalling with activation time 120 seconds:
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
<X>
, where <X> is the time in miliseconds
<X>
, where <X> is the time in miliseconds
35 / 123