6.6.1.3. Power loss
One of the additional options of the equipment is the control of supplying voltage. As
transient power losses can occur in some facilities, you can avoid reporting them by
entering the time after which the information will be sent. The value of the parameter
means that power loss must last for that pre-defined time for the equipment to
recognize it a factual power loss and to send a relevant message.
6.6.2.

Additional data

The Additional data functionality allows for defining kinds of additional data which will be
transmitted together with events to monitoring station via GPRS/SMS. The data may
become valuable information about device's work conditions though it may increase
amount of bytes sent through GSM network. It is possible to define two separate sets of
additional data kinds: for test events (sent periodically according to setting on Access
tab) and for other events. Put a mark next to the name of data kind to turn on
transmission of this data kind to monitoring station. Empty field means that this kind of
data will be not transmitted.
The adjustable parameters are:
 Power status – information about connected charger and battery charging
 GSM status – status about connection to GSM network, type of connection to
server (GPRS/SMS), information about ongoing phone calls
 GSM signal level quality – quality of connection to GSM network (CSQ and BER
parameters)
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
83 / 123