6.3. INPUTS / OUTPUTS

The alarm control unit has 16 configurable zones and 3 software controlled outputs. Zones
can be freely divided into two partitions. Each of zones and outputs has a number of
programmable parameters defined below.
6.3.1.

Zones

6.3.1.1. Zone mode
The parameter allows for determining the stable input line state. Any change of that
state causes alarm message to be sent. Wired input can be NO or NC type. The
following configuration types are available: NO / NC / EOL-NO / EOL-NC / DEOL-NO /
DEOL-NC / Wireless. NC type input must be closed for the whole time. Line
interruption causes its induction. NO type input remains open. It activates when
closed. EOL and DEOL (with parameters or double parameters assigned) differ in the
number of resistors allowing to distinguish alarm from sabotage. Electric diagrams for
all configuration types were described in chapter 3.4.
6.3.1.2. Response type
 Instant – disruption of the line causes immediate alarm, if the system is armed.
 Delay – that type of line is usually used for detectors operation at the facility
entries. The line switches into alarm state after the expiration of programmed
CPX220NWB ALARM CONTROL UNIT – INSTALLER MANUAL
66 / 123