Duration of test
is the time in seconds after which the test will be finished and the
system will return to the main menu.
After activation this function, LEDs 1 – 7 display the zones used in the system. Only
zones belong to the user's partitions are presented. Relevant LED goes off after
violation of the zone. Example of use: walk around the protected object and activate
detectors. After activate detectors, relevant LEDs will go off. LEDs that are still on,
indicate inactive or broken detectors.
To exit the testing function press

7.10. TESTING THE OUTPUTS

The function allow user to test outputs and alarm siren connected to the outputs.
After activation this function, LEDs 1 – 3 display the outputs used in the system. Only
outputs defined as "alarm" type and belong to the user's partitions are presented.
Pressing the key (1-3) activates relevant output (like an alarm), but not reporting the
event to the monitoring station. Thus the siren or other signalling devices can be
checked. Repeated pressing the key, disables the output.
To exit the testing function press
7.11. DURESS CODE
Duress code is used to inform the monitoring station about a distress event. Each
user has his own duress code. User's duress code is his standard code with last digit
increased by one. If the last digit is 9 it should be changed to 0. Example:
User's code is 3446, his duress code is 3447.
User's code is 3449, his duress code is 3440.
Whenever duress code is input and confirmed by
sent. It can be used in every command that requires user authorization, i.e.
arming/disarming and every system option that requires user code, like partition
state checking.
Duress code is disabled by default. It can be enabled by the installer or by the
configuration program.
7.12. EMERGENCY BUTTONS
The keypad of CPX200NB has 3 function keys. Pressing and holding for 3 seconds
one of these keys will generate an alarm
– Fire alarm
2
Works only with KP16 keypad
CPX200NB ALARM CONTROL UNIT – USER MANUAL
EN
or
.
< User code >
or
.
button, distress event will be
2
corresponding to the key:
20 / 30