Examples:
Command: $016
Response: !011
Reads the digital input/output channel status of
module 01.The module returns 0F0000h, which
denotes that the Digital Output is on.
Command:#076
Response:?07
Reads the digital input/output channel status of
module 07.The command is invalid became no
module with the specified address exits
Related Commands:
Section 2.5 #AA00(Data)
Section 2.6 #AA0A(Data)
Section 2.7 #AA1cDD
Section 2.8
Section 2.18 @AA
Section 2.19 @AA(Data)
56/93 I-87211W User Manual V2.5, Oct. 2010