2.11 $AA5
Description:
This command is used to reads the reset status of a module.
Syntax:
$AA5[CHKSUM](CR)
$
Delimiter character
AA
Address of the module in hexadecimal format (00
to FF)
5
Command to read the module reset status
Response:
Valid Command:
Invalid Command:
!
Delimiter for a valid command
?
Delimiter for an invalid command
AA
Address of the module in hexadecimal format (00
to FF)
S
The reset status of the module
1: This is the first time the command has been
sent since the module was powered on
0: This is not the first time the command has been
sent since the module was powered on, which
denotes that there has been no module reset
since the last $AA5 command was sent
!AAS[CHKSUM](CR)
?AA[CHKSUM](CR)