2.9 $AA2
Description:
This command is used to read the module configuration.
Syntax:
$AAN[CHKSUM](CR)
$
Delimiter character
AA
Address of the module in hexadecimal format (00
to FF)
2
Command to read the module configuration
Response:
Valid Command:
Invalid Command: ?AA[CHKSUM](CR)
!
Delimiter for a valid command
?
Delimiter for an invalid command
AA
Address of the module in hexadecimal format (00
to FF)
TT
Type code for the module
40 indicates a DO Module
CC
The BaudRate code for the module. See Section
1.9 for details
FF
Setting for the checksum and the direction of the
counter update for the module. See Section 1.9
for details
!AATTCCFF[CHKSUM](CR)
49/93 I-87211W User Manual V2.5, Oct. 2010