3.1 Installation example: KESSEL Oil / Fuel Separator
Illustration shows KESSEL-oil-/fuel separator class II with cover class B and sampling chamber.
3.2 Dimensioned drawing
OKB
L
L max.
NS
DN
Sludge trap
NS 3
150
1000 l
NS 6
200
2)
2500 l
NS 6
200
2)
5000 l
NS 10
150
1500 l
NS 10
200
2)
2500 l
NS 10
200
2)
5000 l
NS 15
200
5000 l
NS 20
200
4000 l
1) Comparable total sludge trap volume according to dimensioning of DIN EN 858
2) Eccentric reduction of inlet/outlet to DN 150 possible on site, fitted through DN 150 sample removal shaft
3. Installation
T
L
B
min
2390
1200
840
1)
2590
1760
850
3110
1760
870
2910
1200
840
1)
2590
1760
850
3110
1760
870
3110
1760
870
3110
1760
870
B
Oil storage
max
h2
h1
215 l
1240
1100
1070
380 l
1230
1630
1600
470 l
1250
1630
1600
267 l
1240
1100
1070
380 l
1230
1630
1600
470 l
1250
1630
1600
470 l
1250
1630
1600
470 l
1250
1630
1600
DN 150: T-T
DN 200: T-T
T-T
= Height above ground
Class D: 700 mm ≤ T
Class A/B: 700 mm ≤ T
Overhang
Weight
379 kg
90 mm
519 kg
120 mm
594 kg
130 mm
424 kg
100 mm
519 kg
120 mm
594 kg
130 mm
594 kg
130 mm
600 kg
130 mm
30
= 155 mm
= 180 mm
≤ 1.500 mm
≤ 1.800 mm
Total
L
mm
volume
max
2642
1800
2940
4300
3460
5800
3162
2600
2940
4300
3460
5800
3460
5800
3460
5800