Extron electronics DSC 301 HD User Manual page 62

Digital scaling converter
Hide thumbs Also See for DSC 301 HD:
Table of Contents

Advertisement

EDID Minder page
is an EDID management process that manages the EDID information
EDID Minder
between the scaler and one or more input sources. Click the EDID Minder icon (see
figure
35,
, on page 50) on the global navigation bar to open the EDID Minder page
2
(see figure 39).
The EDID properties currently assigned to each input are displayed in the table of inputs
(
). The audio input format listed in an EDID is determined by the audio input format
4
selected on the
Input Configuration
Up to three EDIDs can be stored on the device as custom EDID files. Audio settings from
custom EDID files take priority over current settings on the input.
NOTE: If an analog custom EDID file is assigned to a digital input or a digital custom
EDID file assigned to an analog input, the display may not appear correctly.
1
2
3
Figure 39.
EDID Minder Screen
Filtering available EDID
Use the Filter tab (
) to limit the number of available EDID displayed in the
1
Favorites
, Connected Outputs
1.
From the Resolution drop-down list (
2.
From the Refresh Rate drop-down list (
Assigning EDID
To assign EDID to selected inputs:
1.
In the Inputs panel (table of inputs,
desired inputs
2.
In the Favorites , Available EDIDs , or Connected Outputs panel on the left,
select the desired EDID.
page.
7
4
8
and Available EDIDs panels.
,
) select a specific resolution or Any .
2
) select a specific refresh rate or Any .
3
) on the right, select the checkboxes for the
4
DSC 301 HD • Product Configuration Software