Front panel security lockout — This feature can block all front panel control, or limit
front panel to input selection only. All functions however, are available through RS-232
control.
RS-232 control port — Enables the use of serial commands for complete control
and configuration or integrated into a control system. Extron products use the SIS
Simple Instruction Set command protocol, a set of basic ASCII code commands that
allow for quick and easy programming.
Front-panel USB configuration port — Enables easy configuration without having
to access the rear panel.
1 inch (2.5 cm) high, half rack width metal enclosure
Includes LockIt HDMI cable lacing brackets
Energy-efficient external universal power supply included — Provides worldwide
power compatibility, low power consumption, and reduced operating costs.
ATTENTION:
If not provided with a power supply, this product is intended to be supplied by
a UL Listed power source marked Class 2 or LPS and rated output 12 VDC,
minimum 1.0 A.
Si ce produit ne dispose pas de sa propre source d'alimentation électrique,
il doit être alimenté par une source d'alimentation certifiée UL de classe 2 ou
LPS et paramétré à 12 V et 1,0 A minimum