3. SIGNALS AND WIRING

3.4.3 Terminals

Refer to Section 10.2.1 for the layouts and signal configurations of the terminal blocks.
Connector
Pin No.
1
CNP3
2
3
1
CNP1B
2
3
1
CNP1A
2
3
Connection target
Code
(Application)
L
1
L
Main circuit power
2
L
3
L
11
L
Control circuit power
21
N
Regenerative brake
P
option
C
Protective earth (PE)
www.dadehpardazan.ir 88594014-15
(1) When using a three-phase power supply
Supply L
, L
and L
with three-phase, 200 to 230VAC, 50/60Hz
1
2
3
power.
(2) When using a signal-phase power supply
Supply L
and L
with signal-phase, 200 to 230VAC, 50/60Hz
1
2
power.
Supply L
and L
with single-phase, 200 to 230VAC, 50/60Hz
11
21
power.
Connect the regenerative brake option across P-C.
Keep N open. (Refer to Section 12.1.1)
Connect this terminal to the protective earth (PE) terminals of the
servo motor and control box for grounding.