Terminals - Mitsubishi Electric MR-J2S-*B Series Instruction Manual

General-purpose ac servo. sscnet compatible. servo amplifier
Table of Contents

Advertisement

3. SIGNALS AND WIRING

3.5.2 Terminals

The positions and signal arrangements of the terminal blocks change with the capacity of the servo
amplifier. Refer to Section 10.1.
Connection Target
Symbol
(Application)
L
, L
, L
Main circuit power supply
1
2
3
U, V, W
Servo motor output
Power factor improving DC
P
1
L
, L
Control circuit power supply
11
21
P, C, D
Regenerative brake option
Return converter
N
Brake unit
Protective earth (PE)
Supply L
For 1-phase 230VAC, connect the power supply to L
Power supply
3-phase 200 to 230VAC,
50/60Hz
1-phase 230VAC,
50/60Hz
1-phase 100 to 120VAC,
50/60Hz
Connect to the servo motor power supply terminals (U, V, W).
When not using the power factor improving DC reactor, connect P-P
wired.)
When using the power factor improving DC reactor, disconnect the wiring across
reactor
P
-P
and connect the power factor improving DC reactor across P-P
1
2
Refer to Section 11.2.4.
Supply the following power to L
Power supply
1-phase 200 to 230VAC,
50/60Hz
1-phase 100 to 120VAC,
50/60Hz
1) MR-J2S-350B or less
When using servo amplifier built-in regenerative brake resistor, connect
between P-D terminals. (Wired by default)
When using regenerative brake option, disconnect between P-D terminals and
connect regenerative brake option to P terminal and C terminal.
2) MR-J2S-500B 700B
MR-J2S-500B and 700B do not have D terminal.
When using servo amplifier built-in regenerative brake resistor, connect P
terminal and C terminal. (Wired by default)
When using regenerative brake option, disconnect P terminal and C terminal
and connect regenerative brake option to P terminal and C terminal.
Refer to Section 12.1.1.
When using return converter/brake unit, connect to P terminal and N terminal.
Do not connect to servo amplifier MR-J2S-350B or less.
For details, refer to Section 12.1.2 to 12.1.3.
Connect this terminal to the protective earth (PE) terminals of the servo motor
and control box for grounding.
, L
and L
with the following power:
1
2
3
Servo amplifier
MR-J2S-10B to
, L
11
Servo amplifier
MR-J2S-10B to 700B
3 - 16
Description
/L
and leave L
1
2
MR-J2S-100B
70B
to 22K
L
L
L
1
2
3
L
L
1
2
.
21
MR-J2S-10B1 to 40B1
L
L
11
21
open.
3
MR-J2S-10B1
to 40B1
L
L
1
2
. (Factory-
1
.
1
L
L
11
21