Parameter

4.5
Parameter
When the servo amplifier is connected with the servo system controller, the parameters are set
to the values of the servo system controller. Switching power off, then on makes the values set
on the setup-software invalid and the servo system controller values valid.
NOTES
In the maker setting parameters, do not set any values other than the initial values.
Setting may not be made to some parameters and ranges depending on the model or
version of the servo system controller. For details, refer to the servo system controller user's
manual.
4.5.1

Parameter write inhibit

The release of access to the parameters is established via parameter 40 (parameter write
protection). Parameter No. 40 is made valid by switching power off, then on after setting its
value.
The following table provides an overview over the settings of parameter No. 40:
Setting
0000
(Initial value)
000A
000C
000E
100E
Tab. 4-11: Parameter settings
MELSERVO J2-Super
Function
Operation from controller
Read
Parameter No. 1 to No. 39
Write
Read
Parameter No. 1 to No. 39
Write
Read
Parameter No. 1 to No. 39
Write
Read
Parameter No. 1 to No. 39
Write
Read
Parameter No. 1 to No. 39
Write
Operation from setup-software
Parameter No. 1 to No. 11 and No. 40
Parameter No. 40
Parameter No. 1 to No. 40
Parameter No. 1 to No. 11 and No. 40
Parameter No. 1 to No. 40
Parameter No. 1 to No. 40
Parameter No. 40