Logical inputs
Active mode – requires external voltage (JP2 jumper OFF)
U
 = min +2.5 V
IN-ON
U
 = max +1.5 V
IN-OFF
U
 = +48 V
IN max
I
 (U
 +48 V) = max 1 mA
IN
IN
Passive mode – requires external contact only (JP2 jumper ON)
U
 = approx. 8.3 V
OUT
I
 = approx. 0.5 mA
LOOP
Signalling outputs
5 V or 12V DC voltage
270 ohm current limiter
WIEGAND interface
Input / Output (as programmed)
Module mounting:
®
Power off 2N
Use a hexagonal wrench to unscrew and remove the metal cover.
Use a cross-head screwdriver to unscrew and remove the plastic cover.
Connect the reader module into the 2N
sure that the microphone cable lies under the module.
Use the enclosed screws to fix the reader module to the 2N
Connect the wires for the reader module interface(s) if necessary.
Replace and fix the plastic cover using cross-head screws.
Replace and screw back the metal cover.
Module settings:
Refer to the Configuration manual for 2N IP intercoms for details.
Connection:
IP Vario.
Installation manual 2N® IP Vario
®
 IP Vario basic unit bottom connector making
®
 IP Vario plastic base.
79 /  113