Caution
We recommend the use of a LAN surge protection.
We recommend the use of a shielded SSTP Ethernet cable.
Electric Lock Connection
The electric lock can be connected to terminals 3 and 4 of terminal block X2.
Terminal Block Connection for Electric Lock
Terminals 3 and 4 are connected to a relay on the 2N
act as normally open or normally closed contacts. Configuration is performed through the
configuration connector X1 as described in the
Configuration Connector Connection subsection. Set on the configuration connector whether
the electric lock will be powered from an external or internal power supply.
Installation manual 2N® IP Vario
®
 IP Vario board. The relay terminals may