Stand Mode Illumination Off Time

Specifies the amount of time reader illumination stays off after pulling the
trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in
increments of 500ms (500ms to 16 seconds). See
for a description of this feature.
$CSNTM
Select Stand Mode Time Setting

Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON
state once the state is entered. The range for this setting is from 1 to 255
seconds in 1-second increments. See
description of this feature.
$CSNET05(CR)
Scanning Active Time = 5 seconds
Product Reference Guide
04 = 2 Seconds
DEFAULT
Enter/Exit Programming Mode
page 295
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix D, Keypad
characters in
your desired character(s). End by scanning the
ENTER/EXIT bar code again.
page 296
in "References" for further
$CSNET03(CR)
Scanning Active Time = 3 seconds
DEFAULT
$CSNET08(CR)
Scanning Active Time = 8 seconds