6. ASCII String Command

ASCII string command (DCON protocol) for emitting the IR commands.
Command
#AA0+xx.yyy
#AAn+xx.000
#AAn+xxx.00
#AAn+xxx.000
Note: Firmware version
Example:
1. IR-712A, Modbus Net ID = 27 (0x1B), IR command number = 12, and IR output channel = 1
and 2 [0011(binary)=>3(decimal)].
DCON Command: #1B0+03.012
2. IR-712A, Modbus Net ID = 10 (0x0A), IR command number = 8, and IR output channel = 2.
DCON Command:
(1) #0A2+08.000
(2) #0A2+008.00
(3) #0A2+008.000
IR-712A User Manual
Copyright © 2021 ICP DAS Co., Ltd. All Rights Reserved
 Table 6-1 ASCII String Command
Response
Description
[Request]
>
#: leading character
AA: Module ID (hexadecimal) = Modbus Net ID。
: string "0+"
0+
xx
: String representing decimal value of multiple (or
single) IR output channels. E.g., 03(0x03) means using 2
output channels simultaneously (ch1+ch2).
.: leading character '.'
yyy: String of IR cmd no., e.g. "001", "224".
[Response]
>: response character '>'
[Request]
>
#: leading character
AA: Module ID (hexadecimal) = Modbus Net ID。
: string of decimal value of single IR output ch., n='1'~'2'
n
: character '+'
+
xx / xxx: string representing decimal value of IR cmd no.
^range of "xx": "01"~"99";
^range of "xxx": "001"~"224";
.00 / .000: string ".00" or ".000"
[Response]
>: response character '>'
v1.80 support these commands.
Version 1.9
E-mail: service@icpdas.com