• Run Command" Button
When learning an IR command is finished, users can test this IR command
emitted from the IR-712A by clicking "Run Command" button. The "Output
Channel" combo box specifies the IR output channels.
• "Save this Cmd" Button
This button can save the current learned IR command into the Utility. When
finishing all the learned commands, click Menu [File]->[Save IR Commands to File]
to save all IR commands to an backup file (*.ird).
• "Clear this Cmd" Button
Click "Clear this Cmd" button to remove the learned IR command data
corresponding to the item in the "Command Name" combo box.
• "Clear All Cmds" Button
Click "Clear All Cmd" button to remove all the learned IR command data
corresponding to all the items but not items themselves in the "Command Name"
combo box. Please click Menu [File]->[Unload IR Commands] to clear all IR
commands data as well as reset the names and quantity of the items to the
default in "Command Name" combo box.
• "Output Channel" Combo Box
The "Output Channel" Combo Box specifies the IR output channels when clicking
"Run Command" button to emit the learned IR command. Besides the single
channel 1 and 2 for selection, simultaneous channel 1 and 2 is also provided.
IR-712A User Manual