TPD/VPD Series HMI Device User Manual
For VPD-132-H/132N-H:
0. Run Only: Run the program.
9. USB Force Update: Update a new application to the TouchPAD device through USB.
For VPD-133-H/133N-H:
0. Run & Update (Ethernet): This is a special run mode which is used in the
development stage. The TouchPAD device can be updated by a PC from the remote
side through Ethernet.
1. Ethernet Force Update: While the application run on the TouchPAD device
seriously crashes, use this mode to update a new application to the TouchPAD device
through Ethernet.
2. Run Only: Run the program.
9. USB Force Update: Update a new application to the TouchPAD device through
USB.
7.
USB Port
The USB Port is used to downloading application programs.
8.
I/O Expansion Boards (Optional XV-board)
9.
Reset Button
Use a flat-head screwdriver to press this button to reset the TouchPAD device.
button does not behave as a reboot to the whole system, only resets the microcontroller and this is
not enough to make the program downloading successful. Always cut the power then turn it on
before downloading programs.
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
Optional XV-board
Note: The reset
Page: 36