Page 2
Support ICP DAS take your problem as ours. If you have any problem, please feel free to contact us. You can count on us for quick response. Email: service@icpdas.com Tel: 886-3-5973336 Also, the FTP site of ICP DAS has contents about TouchPAD which you may be interested in.
1. General Specifications 1.1. TPD-28x Series Models TPD-280 TPD-283 Image CPU Module Low-power 32-bit RISC CPU Buzzer Rotary Switch (0~9) Communication Interface Ethernet RJ-45 x 1, 10/100 Base-TX Serial Port RS-485 (including Self-Tuner) MMI (Main Machine Interface) 2.8” TFT (Resolution 240 x 320 x 16), bright pixels <= 3...
1.2 W (50 mA @ 24 V DC ) Consumption Mechanical Dimensions (WxLxH) 76mm (W) x 119mm (L) x 31mm (H) Installation Wall Mount Environmental Operating Temperature -20 ~ +70 °C Storage Temperature -30 ~ +80 °C Ambient Relative Humidity 10 ~ 90% RH, non-condensing 1.3.
Backlight Life 20,000 hours Brightness 400 cd/m2 Touch Panel LED Indicator Audio Earphone Out Reset Button Electrical +10 ~ 30 V DC Power Input Consumption 2.5 W (104 mA @ 24 VDC) Mechanical Dimensions (WxLxH) 126mm(W) x 82mm(L) x 24mm(H) 126mm(W) x 92mm(L) x 29mm(H) Wall Mount Wall Mount...
TPD-280U ** Note: either “Ethernet” or “PoE” uses the same general Ethernet cable. ** PoE, power over Ethernet, means that the Ethernet cable conveys not only data but also power. 3. Setup Device / Connect I/O First of all, you should install HMIWorks in your PC. HMIWorks is the development tools for TouchPAD programs.
3.1.1. Setup TPD-280 Configuration mode: In the back of the TPD-280, configuration modes can be found. Use the rotary switch to set the configuration mode. Mode Description This mode is used for running programs. Run Only This mode is used for updating programs.
3.1.2. Setup TPD-283 Configuration mode: In the back of the TPD-283, configuration modes can be found. Use the rotary switch to set the configuration mode. Mode Description This is a special run mode which is used in the Run & development phase.
Page 14
“Search TouchPad …” first. Clicking on the searched TPD-283 shows the “Setup Ethernet Device” window. Choose the IP type, DHCP or Static, for the new program and then press OK. Run Run to download the new program. Note1: MAC address can be found in the back of TPD-283. HMIWorks uses MAC to search TouchPAD.
Page 16
TPD-283. HMIWorks can download programs through that USB port. Unlike TPD-280 and TPD-283, Users need not “Setup Device” in the Run menu but users must install USB driver in their PC first instead. Install TouchPAD USB Driver To install DFU (Device Firmware Update) driver allows user to download programs to TouchPAD via USB port.
Start In back of After resetting , the TouchPAD following screen should Rotary Switch set to 9 be seen. Reset Run Run (F9) Download the program by Run Run In back of Rotary Switch set to 0 TouchPAD Reset Refer to the user manual to update OS through USB and do calibration.
Page 18
Specify the connection methods, TCPIP or UART, to Connection connect to the I/O module. Specify the name of the I/O module. Users can assign a Device Name name they want. Specify the modal of the I/O module to connect. Modal Name The specified ID of the I/O module in the network.
Click the I/O module you want and then press “OK” to add tags of the specified I/O module. Assign the “Device Name”, press “OK” and then you can see the I/O module is added to the Workspace. 4. Development Tool, HMIWorks 4.1.
Choose the target module, Orientation, and the Default Programming Type. Press OK and HMIWorks integrated design environment shows as below. Menu bar Frame Design Space Inspector Workspace Libraries Toolbox Results window (Output and Errors) Status bar 4.2. Ladder Designer Click HMI menu to use this feature. Users can manage their ladder design in the Workspace.
4.2.1. Getting Started To use Ladder Designer, HMIWorks_Standard.exe first. Then create a new project. 4.2.2. Introduction to Ladder Designer A Ladder Designer is a tool to implement the ladder logic according to users’ design. Press F4 to open Ladder Designer. The briefings of the function bar: Item Description...
Page 22
Insert a Jump which is parallel to the cursor The briefings of the contact type: Item Description A normally-open contact A normally-closed contact A positive transition contact when the state from OFF to ON, trigger one shot A negative transition contact ...
else eno = 0; return; 4.2.3. Operations of Ladder Designer 4.2.3.1. New Virtual Tags (F2) To use Ladder Designer, add tags (variabls) for Ladder Designer first. Press F2 (HMI New Virtual Tag) to add virtual tags, an “Edit variable” window shows.
delete a contact Move the cursor to the contact / coil you want to delete. Then press the “delete” key. /coil Double-click on the contact/coil to evoke the “Select Associate tags to variable” window to associate tags to it. contact /coil Change types of Move the cursor to a contact /coil and then press the contact /coil...
The second method: double click on the widget on the frame design space to evoke the “Select variable” window. And then double click on the tag you want to associate with the widget. The third method is click on the “…” button of the TagName property in the inspector of the Widget to evoke the “Select variable”...
Page 26
Widget: TextPushButton: create a button. Slider: show or decide the percentage. BitButton: create an image button. HotSpot: create a hot spot that can issue an OnClick event. CheckBox: provide an alternative. Label: provide a string that can be modified during run-time. System: Timer: periodically execute codes.
TextAsImage Text Set to true to take effect the property Font Picture Picture The Picture property is used to load a image for the tool, Picture HiColor Picture Set to true for 16-bit color representation for loading image. Thus it can prevent not-smooth gradient phenomenon of the loading picture but costs more storage space.
5. Make a Simple Project 5.1. Integrate TPD-280 with I/O In this example, we use TPD-280 to control an I-7066, the relay output module of ICP DAS. First, put I-7066 in the same RS-485 network of TPD-280 and configure I-7066 with DCON Utility (baudrate, data bit, parity, stop bit, Net ID).
Page 29
3. Setup Device Refer to “Setup Devices” in the chapter 3 for details. 4. Compile and Download to Run After connecting to TouchPAD, press F9 to run (or Run Run). As the following figure shows, pressing the button changes the output of channel 0 of the I-7066. TouchPAD Compact User Manual, version 1.0.4.