TPD/VPD Series HMI Device User Manual
8.
Rotary Switch (0 ~ 9)
The Rotary Switch is used to set the configuration modes, as follows:
For TPD-430/430-EU/433/433-EU:
0. Run: This mode is used to run the application. (Only one application on a TouchPAD)
1. Update OS: Update operating system of TouchPAD.
9. Update AP: Download an application to TouchPAD.
For TPD-430-H/430-H-EU:
0. Run Only: Run the program.
9. USB Force Update: Update a new application to the TouchPAD device through USB.
For TPD-433-H/433-H-EU:
0. Run & Update (Ethernet): This is a special run mode which is used in the
development stage. The TouchPAD device can be updated by a PC from the remote
side through Ethernet.
1. Ethernet Force Update: While the application run on the TouchPAD device seriously
crashes, use this mode to update a new application to the TouchPAD device through
Ethernet.
2. Run Only: Run the program.
9. USB Force Update: Update a new application to the TouchPAD device through USB.
9.
Reset Button (Left had Side)
Use a flat-head screwdriver to press this button to reset the TouchPAD device.
button does not behave as a reboot to the whole system, only resets the microcontroller and this is
not enough to make the program downloading successful. Always cut the power then turn it on
before downloading programs.
Copyright © 2017 ICP DAS Co., Ltd. All Rights Reserved.
Note: The reset