1
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
2
If you have not already changed your personal code number, use the default setting – 1111.
3
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will
also provide the link quality indication – see PowerMaster-360 Installer's Guide.
4
To skip the SIRENS TEST and select the other devices TEST, press
The Periodic test can be performed on a maximum of two wireless sirens and the sirens of enrolled smoke
5
sensors. Outdoor sirens are activated with low volume.
If no temperature sensor is enrolled in the system, the display reads
6
The displayed temperature can be in Celsius or Fahrenheit according to the programmed settings of the
7
Temperature Sensor.
8
To activate system devices during the "Periodic Test"; make sure the device LED lights when activated:
Contact sensor:
Motion sensors:
Smoke sensors:
Keyfob:
Keypads:
Repeater:
Other devices:
9
a. Three seconds after the device is displayed, the device LED blinks to assist you to identify ("it's me").
b. To end the session, press the
.
10
Testing emails must first be configured (see Chapter 4, B.12 "EMAIL BY SERVER").

Periodic test per partition

In addition to the regular Periodic Test, you can also test zones for enrolled sensors (excluding temperature
sensors and sirens) that are assigned to a selected partition.
A. To conduct the periodic test per partition
1.
P1:R P2:N P3:-
MEMORY
TROUBLE
2.
SELECT PARTITION
3.
Partition 1
4.
PERIODIC TEST
5.
ENTER CODE: 
6.
CODE
P1 SENSORS TEST
7.
8.
NOT ACTIVE NNN
D-307082 PowerMaster 360 User's Guide
Additional Information (Periodic Test)
Open or close the door or window protected by the contact.
Perform a "walk test" of the detector as explained in the detector's datasheet.
Perform a "Diagnostic test" as explained in the detector's datasheet.
Activate any of the keyfob buttons.
Perform a disarm or arm routine or press any other key that activates the LED.
Follow the "Diagnostic Tests" described in the repeater's datasheet.
In general, follow the "Diagnostic Tests" described in the device's datasheet or
activate any of its functions.
button until the display reads [<OK> TO EXIT] and then press
1
Make sure the selected partition is disarmed and the other partitions are not
in exit or entry delay and then press the partition (
When the display reads [SELECT PARTITION], press the partition number of
the zones you wish to test, for example,
Press the
and press
The screen will now prompt you to enter your Master user code.
Enter your Master user code.
3
To enter the devices test procedure per partition, press
The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled
TESTING THE SYSTEM
"NO EXISTING DEV.
button repeatedly until the display reads [PERIODIC TEST]
.
2
.
".
) button.
(Partition 1).
.