TESTING THE SYSTEM
C. To display the temperature and
light intensity
TEMP/LIGHT TEST
7.
8.
Z01 24.5C
Z01:LIGHT (**)
Z01:Temp. Sensor
Guest room
9.
DEVICE TESTS END
or
D. To test all other devices
TEST ALL DEVICES
10.
NOT ACTIVE NNN
11.
Z01 NOT ACTIVE NNN
Z01 CONTACT
FRONT DOOR
12.
13.
DEVICE TESTS END
READY 00:00
or
E. To test Emails
14.
E-MAIL TEST
15.
Please wait...
Pls chck MailBox
16.
Return to step 14
46
The display now reads [TEMP/LIGHT TEST].
To display the temperature or light intensity of zones on the control panel,
press
.
6
The panel reads the temperature and light intensity of each zone. The display
alternates between the temperature, the light intensity, the sensor number
and the sensor location.
Repeatedly click the
intensity of each zone.
When the temperature of all zones has been reviewed, the display reads
[DEVICE TESTS END]. Press the
test and then move to the next step to test the other devices.
The display now reads [TEST ALL DEVICES].
To enter the devices test procedure, press
The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled
devices in the panel that have not been tested yet. This number automatically
drops one count for every tested device. To initiate devices test, press
The display shows the 1
alternates between the device number, the device type (e.g. magnetic
contact, keyfob, keypad, etc.), and the device location.
The test is performed by activating each device as explained in point 8 in the
Additional Information table below.
Click
to scroll through the list of all untested devices.
When all devices have been activated, the display reads [DEVICE TESTS
END] followed by [READY 00:00].
Press the
or the
the next step to test the email.
The display now reads [E-MAIL TEST].
To enter the email test procedure, press
Check the private email inbox to view the sent email.
7
button to review the temperature and light
or the
st
device in the list of untested devices. The display
button to confirm the test and then move to
10
D-307082 PowerMaster 360 User's Guide
button to confirm the
.
9
.
.