8: Annunciators; Ann-Bus Setup - Honeywell Fire-Lite Alarms ES-200X Manual

Addressable fire alarm control panel
Hide thumbs Also See for Fire-Lite Alarms ES-200X:
Table of Contents

Advertisement

Programming
OFF_NORMAL_MESSAGE
24_HOUR_TEST
24 HOUR ABNORMAL TES
UPDOWN REQUEST
UPLOAD SUCCESS
DOWNLOAD SUCCESS
UPDOWN FAILURE
GENERAL ALARM
GENERAL SUPERVISORY
3.6.8 Annunciators
PROGRAMMING
1=HISTORY
2=COMMUNICATOR
3=ANNUNCIATORS
Programming Screen #3
A printer module, graphic annunciator module, LCD annunciator module, LED annunciator module, and relay module can be pro-
grammed into the ES-200X system. These devices communicate with the FACP over the ANN-BUS terminals on the control panel.

ANN-BUS Setup

ANNUNCIATORS
1=PRIMARY
2=SECONDARY
3=ANN-BUS OPTIONS
Annunciators Screen
ANN-BUS Enabled
The ANN-BUS must be enabled if any modules are connected to the ANN-BUS terminals. To enable the ANN-BUS, press 1 while
viewing ANN-BUS screen #1 so that the display reads ANN XXX Enabled Yes. Each press of the 1 key will cause the display to toggle
between ANN XXX Enabled Yes and ANN XXX Enabled No.
Modules Installed
ANN XXX
1=ENABLED
2=MODULES INSTALLED
3=AUTO-CONFIGURE
ANN XXX Screen #1
Pressing the down arrow key will allow the programmer to view additional screens displaying Addresses 1-8. To select one or more
addresses for the installed module(s), press the number key corresponding to the module address in each screen. The following screen
will be displayed for each address:
90
308
602
608
411
416
412
413
000
000
Table 3.3 Event Codes (Continued)
Pressing 3 while viewing Programming Screen #3 will cause the control panel to display the following
screens:
1=PRIMARY
2=SECONDARY
3=ANN-BUS OPTIONS
Two ANN-BUS circuits are available on the ES-200X. Press 1 to configure the Primary ANN-BUS or press
2 to configure the Secondary ANN-BUS. The following screens will be displayed for either ANN-BUS cir-
cuit where (XXX) indicates either Primary or Secondary.
ANN XXX
1=ENABLED
2=MODULES INSTALLED
3=AUTO-CONFIGURE
ANN-BUS Screen #1
If an ANN-BUS module is installed, press 2 for Modules Installed to select ANN-BUS addresses for the
NO
module(s). The only difference between the two programming screens are the addresses. The Primary Bus
module addresses will have a prefix of "1-" while the Secondary Bus module addresses will have a prefix
of "2-". The following screen will be displayed for either bus circuit.
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
ANN-BUS SELECT
NO
ANN-BUS MODULES
1=ADDR. X-1
NONE
2=ADDR. X-2
NONE
3=ADDR. X-3
NONE
ANN-BUS Modules Screen #1
ANN-BUS MODULE X-1
ANN-BUS ADDRESS
1=TYPE
NONE
ANN-BUS Address Screen
ES-200X Series Manual — P/N LS10131-000FL-E:C 7/25/2018
Master Programming Level
LB
RP
RY
RB
RS
RS
RR
00
00
ANN XXX
1=CLASS A
NO
ANN-BUS Screen #2
LX
00
00