Programming
Active/Alarm
Active/Alarm
Active/Alarm
Active/Alarm
Active/Alarm
Active/Alarm
The LED assignments for the modules annunciating Point Ranges 061 - 090 and 091 - 099, will follow the same pattern as the second
ANN-RLED module.
ANN-LED Point Option - Alarm, Trouble and Supervisory
If Point is selected as the module option, and the module is programmed to annunciate alarms, troubles and supervisories, the first ten
LEDs on the first ANN-LED module will display the system status information. The remaining 30 LEDs on the first module and the last
30 LEDs on the remaining modules will display the alarm, trouble and supervisory status for each of the ten zones in the Point Range
programmed for that particular module. The LED assignments for each ANN-LED module will be as follows.
Alarm Silenced
The LED assignments for the modules annunciating Point Ranges 021 - 030, 031 - 040 and 041 - 050, 051 - 060, 061 - 070, 071 - 080,
081 - 090, and 091 - 099, will follow the same pattern as the second ANN-LED Module.
96
Not Used
Not Used
Not Used
Not Used
Point 031
Point 032
Active/Alarm
Point 036
Point 037
Active/Alarm
Point 041
Point 042
Active/Alarm
Point 046
Point 047
Active/Alarm
Point 051
Point 052
Active/Alarm
Point 056
Point 057
Active/Alarm
Table 3.9 ANN-RLED Module #2 (Point Range 031 - 060)
NAC 1 Fault
Earth Fault
Battery Fault
Point 001
Point 002
Active/Alarm
Active/Alarm
Point 001
Point 002
Trouble
Trouble
Point 001
Point 002
Supervisory
Supervisory
Point 006
Point 007
Active/Alarm
Active/Alarm
Point 006
Point 007
Trouble
Trouble
Point 006
Point 007
Supervisory
Supervisory
Table 3.10 ANN-LED Module #1 (Point Range 001 - 010)
Not Used
Not Used
Not Used
Not Used
Point 011
Point 012
Active/Alarm
Active/Alarm
Point 011
Point 012
Trouble
Trouble
Point 011
Point 012
Supervisory
Supervisory
Point 016
Point 017
Active/Alarm
Active/Alarm
Point 016
Point 017
Trouble
Trouble
Point 016
Point 017
Supervisory
Supervisory
Table 3.11 ANN-LED Module #2 (Point Range 011 - 020)
Not Used
Not Used
Not Used
Not Used
Point 033
Point 034
Active/Alarm
Active/Alarm
Point 038
Point 039
Active/Alarm
Active/Alarm
Point 043
Point 044
Active/Alarm
Active/Alarm
Point 048
Point 049
Active/Alarm
Active/Alarm
Point 053
Point 064
Active/Alarm
Active/Alarm
Point 058
Point 059
Active/Alarm
Active/Alarm
NAC 2 Fault
NAC 3 Fault
Charger Fault
Disabled
Point 003
Point 004
Active/Alarm
Active/Alarm
Point 003
Point 004
Trouble
Trouble
Point 003
Point 004
Supervisory
Supervisory
Point 008
Point 009
Active/Alarm
Active/Alarm
Point 008
Point 009
Trouble
Trouble
Point 008
Point 009
Supervisory
Supervisory
Not Used
Not Used
Not Used
Not Used
Point 013
Point 014
Active/Alarm
Active/Alarm
Point 013
Point 014
Trouble
Trouble
Point 013
Point 014
Supervisory
Supervisory
Point 018
Point 019
Active/Alarm
Active/Alarm
Point 018
Point 019
Trouble
Trouble
Point 018
Point 019
Supervisory
Supervisory
ES-200X Series Manual — P/N LS10131-000FL-E:C 7/25/2018
Master Programming Level
Not Used
Not Used
Point 035
Active/Alarm
Point 040
Active/Alarm
Point 045
Active/Alarm
Point 050
Active/Alarm
Point 055
Active/Alarm
Point 060
Active/Alarm
NAC 4 Fault
Maintenance
Point 005
Active/Alarm
Point 005
Trouble
Point 005
Supervisory
Point 010
Active/Alarm
Point 010
Trouble
Point 010
Supervisory
Not Used
Not Used
Point 015
Active/Alarm
Point 015
Trouble
Point 015
Supervisory
Point 020
Active/Alarm
Point 020
Trouble
Point 020
Supervisory