Programming
Date
To change the date, press 2 while viewing the Time-Date Screen. The following screen will be displayed:
A flashing cursor is located toward the top left of the display. Below the cursor is the current date. To change the date, enter the two-digit
month followed by the two-digit day and then the two-digit year (17 for 2017, 18 for 2018, etc.). The cursor will move one position to
the right each time a digit is entered. After the last year digit is entered, the display will return to the Time-Date Screen which will show
the new date entry. If an error is made while entering a digit, press the CLR key to delete the entire entry and beginning again.
Clock Format
The clock can be configured to display 12 hour (AM & PM) or 24 hour (military) time. Pressing 3 while viewing the Time-Date screen
will cause the display to toggle between 12HR and 24HR. Select 12HR for 12 hour display or 24HR for 24 hour display.Note:
NOTE: If the clock is changed to 24 hour (military) format, the date will change to the European standard of Day-Month-Year (for display
purposes only).
Daylight Savings Time
TIME AND DATE
1=DAYLIGHT SAVINGS
Time & Date Screen #2
Pressing 1 while viewing Daylight Savings Screen #1 will cause the display to toggle between Enabled Yes and Enabled No. The control
panel will automatically update the time for daylight savings time when Enabled Yes is selected.
Pressing 2 while viewing Daylight Savings Screen #1 will display another screen which allows the programmer to select the month that
daylight savings time will begin. In this sub-screen, pressing 1 will select March, 2 will select April, and 3 will select May.
Pressing 3 while viewing Daylight Savings Screen #1 will display two sub-screens which allow the programmer to select the week of the
month that daylight savings time will begin. In the first sub-screen, pressing 1 will select the first week, 2 will select the second week
and 3 will select the third week, while in the second sub-screen, pressing 1 will select the fourth week and 2 will select the last week of
the selected month.
Pressing 1 while viewing Daylight Savings Screen #2 will display another screen which allows the programmer to select the month that
daylight savings time will end. In this sub-screen, pressing 1 will select September, 2 will select October, and 3 will select November.
Pressing 2 while viewing Daylight Savings Screen #2 will display two sub-screens which allow the programmer to select the week of the
month that daylight savings time will end. In the first sub-screen, pressing 1 will select the first week, 2 will select the second week and
3 will select the third week, while in the second sub-screen, pressing 4 will select the fourth week and 5 will select the last week of the
selected month.

Timers

SYSTEM SETUP
1=TIMERS
2=NAC
3=RELAYS
System Setup Screen #2
PAS (Positive Alarm Sequence) Delay
TIMERS
1=PAS DELAY
000
2=PRE SIGNAL
000
3=WATERFLOW
000
Timer Screen #1
A flashing cursor is positioned in the lower left corner of the display. Enter a delay time consisting of three digits, such as 005 for five
seconds. Upon entering the third digit, the time delay will be stored in the control panel memory and the display will return to the Delay
Screen which will indicate the new delay time.
74
ENTER DATE
MONTH DAY YEAR
05-04-17
Pressing 1 while viewing Time-Date Screen #2 will cause the following screens to be displayed:
DAYLIGHT SAVINGS
1=ENABLED
YES
2=START MONTH
3=START WEEK
WEEK-2
Daylight Savings Screen #1
Timer delays for PAS, Pre-signal and waterflow activation can be programmed by pressing 1 while viewing
System Setup Screen #2. The following screen will be displayed:
TIMERS
1=PAS DELAY
000
2=PRE SIGNAL
000
3=WATERFLOW
000
Timer Screen #1
The factory default setting for PAS is 000 for no delay. To select a PAS delay of 001 to 180 seconds for all
devices programmed for PAS, press 1 while viewing Timer Screen #1. The following display will appear:
PAS DELAY
RANGE 0-180 SECONDS

PAS Delay Screen
Date Screen
DAYLIGHT SAVINGS
1=END MONTH
2=END WEEK
MAR
Daylight Savings Screen #2
TIMERS
1=AC LOSS DELAY
2=CTRL MOD DLY
Timer Screen #2
ES-200X Series Manual — P/N LS10131-000FL-E:C 7/25/2018
Master Programming Level
NOV
WEEK-1
2
000