Multi Edit Mode
CONTROLS Page
Mode
Continuous Controllers can be set to the following modes: Off, or MIDI CC.
When Mode is set to Off, the controller is disabled for this zone.
When Mode is set to MIDI CC, the controller can send MIDI control messages.
Destination
Use the Destination field to select a parameter to control.
Destinations 0-127 are MIDI continuous controller messages (CC numbers), which can be
used to control K2700 Program parameters, or external MIDI gear.
CC numbers that are assigned to Program parameters will show the parameter name next to
the CC number. These CC numbers will control the Program in the current Zone.
Destinations 128 and greater can be used to control K2700 Program and Multi functions.
For details see
"The Controller Destination List" on page
7-21.
Scale
Use the Scale parameter to change the range of CC values sent by the controller (in
combination with the Add and Curve parameters). The Scale parameter multiplies the CC
values sent, changing the lowest and highest values sent by the controller. MIDI controllers
are limited to sending values from 0-127, even if the Scale and Add parameters are set to
produce values outside of this range.
By default, each continuous controller sends CC values 0-127, 0 at its lowest position, and
127 at its highest position. These values can be multiplied by the percent value of the Scale
parameter in order to change the range of CC values. For example:
When when Scale is set to 100% (with Add set to 0 and Curve set to Linear), the controller
sends CC values 0-127, 0 at its lowest position, and 127 at its highest position.
Scale values 1-99% make the controller send a smaller range of CC values, allowing for finer
control of CC values. When Scale is set to 50% (with Add set to 0 and Curve set to Linear),
the controller sends CC values 0-63, 0 at its lowest position, and 63 at its highest position.
Scale values 101-300% make the controller send a values 0-127 over a smaller range of
controller positions, allowing for coarser control of CC values. When Scale is set to 200%
(with Add set to 0 and Curve set to Linear), the controller sends CC values 0-127, 0 at its
lowest position, and 127 at its middle position through its highest position.
When Scale is set to a negative number, the controller range is reversed. For example, when
Scale is set to -100% (with Add set to 0 and Curve set to Linear), the controller sends CC
values 127-0, 127 at its lowest position, and 0 at its highest position.