Connection Of Power Supply; Connection Of Control Unit; Connection Of Nc Keyboard - Mitsubishi Electric MELDAS 60 Series Maintenance Manual

Hide thumbs Also See for MELDAS 60 Series:
Table of Contents

Advertisement

5.3.2 Connection of Power Supply

24VDC is supplied from the CR01-1 cable enclosed with FCU6-DUN33.

5.3.3 Connection of Control Unit

Connect the cable from the control unit to the "CR02" connector on the back of the communication
terminal.

5.3.4 Connection of NC Keyboard

Connect to the "J1" connector on the NC keyboard with the CR03 cable connected to the "CR03"
connector. Connect the J2 cable for the menu keys to the "J2" connector on the NC keyboard.
CAUTION
Downloaded from
ManualsNet.com
5. COMMUNICATION TERMINAL
5.3 FCU6-DUN33 Display Unit (10.4-type color LCD)
CR01-1 cable
CR01
CBP18
CR02
FCU6-KB021/031
J1
J2
Do not apply voltages other than those indicated in this manual on the connector.
Doing so may lead to destruction or damage.
Incorrect connections may damage the devices, so connect the cables to the specified
connectors.
search engine
FCUA-R220 cable
Stabilized power supply
Connect
24VDC
0V(RG)
FG
FG
AC(H)
AC(N)
SH21 cable
(FCUA-R000 cable)
The partner side connection is "AUX1".
(The connection position differs according
to the control unit.)
CR03 cable
J2 cable
I-43
Select a stabilized power supply that
satisfies the following specifications.
Output voltage: 24VDC ± 5%
Ripple: ±5% [p-p]
Rated current: 24VDC, 0.9A or more
Ex.FCA64
AUX1
CR03

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meldas 60s series

Table of Contents