Appendix 2.15 FCUA-R220 Cable Manufacturing Drawing (24VDC input)

Application:
Assembly drawing
Connection diagram
Manufacturing precautions
(1) The wire material shall be a shielded, 1-pair stranded cable equivalent to AWG18 (0.75mm
cable is 15m or longer, select AWG16 (1.25mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position designated
in the assembly drawing.
(4) Install each crimp terminal side after stamping the name of each signal on the mark tube.
(5) Protect both ends of the wire material with insulation bushing.
(6) Use AWG18 (0.75mm
Downloaded from
ManualsNet.com
APPENDIX 2 CABLE DRAWINGS
Appendix 2.15 FCUA-R220 Cable Manufacturing Drawing
Supply of 24VDC to remote I/O unit
and communication terminal.
FG
3
GND
2
+24V
1
2
) or equivalent for the shield treatment wire material.
search engine
Option (compatible connector set)
FCUA-CN220
(Note that this corresponds only to the connector
on the control unit side.)
List of parts used
Part name/
No.
model
Connector
1
2-178288-3
Contact
2
1-175218-5
Wire material
3
JPVV-SB
2
1P × 0.75mm
Crimp terminal
4
V1.25-3
WHITE
BROWN
2
) wire material or equivalent.
I-211
Manufacturer
Q'ty
Tyco Electronics
1
AMP
Tyco Electronics
3
AMP
BANDO Electric
(1)
Wire
JST
3
Max. cable length: 30m
FG
GND
+24V
2