Machine output terminal
CFD83
1
18
(3) Rotary switch
Set the address (station No.) assignment for two stations in DI/DO: 64/48 point units. Set using the
CS1 rotary switch. The assignment address is changed with the rotary switch setting.
∗ The X
DI/DO assignment No. to the head address assigned to each remote IO unit station No.
(4) Setting switches
Set the digital input sink type and source type changeover.
Downloaded from
ManualsNet.com
11. CONNECTION OF QY231 EXTENDED I/O CARD
33
<Cable side connector type>
Connector : MRP50M01
Contact : MRPM102
Case : MR50W
Recommended manufacturer :
HONDA TSUSHIN KOGYO
50
CS1
Setting
0
Remote I/O station 0, 1 station selection
1
Invalid
2
Remote I/O station 2, 3 station selection
3
Invalid
4
Remote I/O station 4, 5 station selection
5
Invalid
6
Remote I/O station 6, 7 station selection
7
Invalid
8~F
Setting prohibited
and Y
assignments are reference values. When actually making the assignment, add
S1, S2
S3, S4
ON
OFF
OFF
ON
search engine
11.2 Hardware Interface
1
Y08
2
Y0B
3
Y0E
4
Y01
5
Y04
6
Y07
7
Y1A
8
Y1D
9
Y1F
10
Y12
11
Y15
12
Y28
13
Y2B
14
Y2E
15
Y21
16
Y24
17
Y26
18
0V(RG)
CS1
0
Function
Function
Source input selection
Sink input selection
I-154
CFD83
33
24VDC
34
19
Y09
35
20
Y0C
36
21
Y0F
37
22
Y02
38
23
Y05
39
24
Y18
40
Y1C
25
Y1B
41
26
Y10
42
27
Y13
43
28
Y16
44
29
Y29
45
30
Y2C
46
31
Y2F
47
32
Y22
48
49
50
* This examples shows CS1 set to
※CS1 を「0」に設定した場合の例です。
"0" and CS2 set to "1".
詳細は PLC インターフェース説明書を
Refer to the PLC Interface Manual
参照してください。
for details.
0
CS1
Y0A
Y0D
Y00
Y03
Y06
Y19
Y1E
Y11
Y14
Y17
Y2A
Y2D
Y20
Y23
Y25
Y27

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meldas 60s series

Table of Contents