2.2 List of Configuration Units

2.2.1 Control Unit

(1) Control unit
Type
FCU6-MU011
FCU6-MU015
FCU6-MU021
FCU6-MU023
FCU6-MU032
FCU6-MA031
(2) Control unit options
Type
HR513
HR571
FCU6-EP203-1
HR576
Downloaded from
ManualsNet.com
2.2 List of Configuration Units
Function
M64 control unit set
FCA64A-B, FCA64-B system
compatible unit
M64 control unit set
FCA64-P (optical) system
compatible unit
M65 control unit set
FCA65-A, FCA65-P1 system
compatible unit
M65 control unit set
FCA65-P1 (optical) system
compatible unit
FCA65V-P1 (optical) system
compatible unit
M64AS/64S/65S control unit
set
FCA64AS/64S/65S system
compatible unit
M66/M66S control unit set
FCA66-A/FCA66S system
compatible unit
Function
External PLC link II (bus
connection, interface)
Mounted into control unit's
extension slot
External PLC link I (M-NET
interface)
Mounted into control unit's
extension slot
(1) High-speed program
server
(2) Data input/output
Ethernet communication
IC card
CC-Link card
search engine
2. CONFIGURATION
Configuration element
Main control card (HR113)
24V input power supply card (HR083)
Communication card (HR531)
Case set
Main control card (HR113)
24V input power supply card (HR083)
Communication card (HR541)
Case set
Main control card (HR114)
24V input power supply card (HR083)
Communication card (HR171)
Case set
Main control card (HR114)
24V input power supply card (HR083)
Communication card (HR541)
Case set
Main control card (HR116)
24V input power supply card (HR083)
Communication card (HR171)
Case set
Main control card (HR146)
24V input power supply card (HR083)
Communication card (HR171)
Case set
Configuration element
Control card (HR513)
Control card (HR571)
Control card for IC card (HR831)
Communication card for Ethernet
(HR832)
Connection cable
Control card (HR576)
I-4
Details
Export Trade Control Ordinance and
Foreign Trade Ordinance
noncompliant unit
Export Trade Control Ordinance and
Foreign Trade Ordinance
noncompliant unit
Export Trade Control Ordinance and
Foreign Trade Ordinance
noncompliant unit
Export Trade Control Ordinance and
Foreign Trade Ordinance
noncompliant unit
Use when there is no high-speed
program server function
Use FCU6-MA031 when server
function is provided
Export Trade Control Ordinance and
Foreign Trade Ordinance
noncompliant unit
M64AS is used as a set with
FCU6-HR410
M64S is used as a set with
FCU6-HR411
M65S is used as a set with
FCU6-HR415
Export Trade Control Ordinance and
Foreign Trade Ordinance
compliant unit
M66S is used as a set with
FCU6-HR415
Details
Dedicated for MELDAS60/60S
series
Type connected to MELSEC
A1S, A N, A A, A U Series
Dedicated for MELDAS60 series
Type connected to MELSEC
AJ71C22 unit (serial link)
(1) Dedicated for MELDAS64S/
65/65S/66/66S
(2) Dedicated for MELDAS60S
series
ATA memory card interface +
Ethernet interface
Dedicated for MELDAS60S series

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meldas 60s series