5.2 Connection of Power Supply

The 24VDC must be supplied to the communication terminal.
Prepare a stabilized power supply that satisfies the following conditions.
The 9-type CRT type requires 100VAC for the CRT power supply.
Type
Power voltage
Instantaneous power failure
tolerable time
Current consumption
5.2.1 Connection of Power Supply to 7.2-type Monochrome LCD
(FCUA-LD100/FCUA-LD10+KB20)
Supply 24VDC to the CR01 connector on the rear of the LCD.
[FCUA-LD100/LD10+KB20 rear side]
J1
J2
CAUTION
Separate the signal wire from the drive line/power line when wiring.
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
Incorrect connections may damage the devices, so connect the cables to the specified
connectors.
5. CONNECTION OF COMMUNICATION TERMINAL
5.2 Connection of Power Supply
FCUA-LD100/
LD10
Follows specifications of 24VDC power supply being used
24VDC, 0.9A
Recommended adaptive connector
(Enclosed with FCUA-LD100/FCUA-LD10+KB20)
Connector : 2-178288-3
Contact
: 1-175218-5 (tin plated) (Tyco Electronics AMP)
Y
FG 3
0V 2
24VDC(+) 1
LCD
CR03
CR02
CR05
CR06
I - 49
Get other manuals https://www.bkmanuals.com
FCU6-DUT32
24VDC±5%
Ripple ±5% (p-p)
24VDC, 0.9A
R220 cable
FG
CR01
CNZ24
FCUA-CT100/
CT120/KB10
24VDC, 0.6A
24VDC(+)
0V
FG
Stabilized
power supply