Hr571 Card - Mitsubishi Electric MELDAS 60 Series Maintenance Manual

Hide thumbs Also See for MELDAS 60 Series:
Table of Contents

Advertisement

1.13 HR571 Card

[Block diagram]
[Explanation of functions]
This is used in the M-NET interface which is one of interface with the sequencer.
TS1 M-NET (RS-422 multidrop)
(Note) The ISP connector and TEST connector on the HR571 card cannot be used.
[Connector layout diagram]
[Explanation of settings]
SW1 (R-TERMINAL)
SW2
[Explanation of LEDs]
Name
RUN
RD
SD
ALM
Downloaded from
ManualsNet.com
1. EXPLANATION OF MODULE FUNCTIONS
RT-BUS
SW2
SW1
TEST
Setting
Terminator (Down: Terminator ON)
Rotary switch (Normal: 0. Refer to the Operation Manual.)
Function
Software operation check
Reception status check
Transmission status check
Communication error
display
search engine
1.13 HR571 Card
CPU
2-port
SRAM
RAM
(32kB)
(8kB)
RUN
SD
ISP
RD
ALM
Explanation
Status
Color
When
During
normal
error
ON or
Green Flickers
Contact the Mitsubishi Service Center
OFF
Check communication cable connection
Green
Lit
Not lit
Check rotary switch setting No.
Green
Lit
Not lit Check rotary switch setting No.
Red
Not lit
Lit
Contact the Mitsubishi Service Center
II-25
TS1
TS1
RTBUS
Correspondence for error

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meldas 60s series

Table of Contents