Figure 10
Every 6 months, the following measures are required:
Check the hydrometer display (2) in the sight-glass. There is an opening (1) in the wooden
crate to enable you to perform this check. If the 70% indicator field has changed colour, the
maximum admissible atmospheric humidity has been exceeded. In this case, the tur-
bocharger or cartridge group must be checked and repackaged by an ABB Turbocharging
Service Station.
Check the package for damage. If the package is damaged, the turbocharger or cartridge
group must be checked and repackaged by an ABB Turbocharging Service Station.
After every 3 years, the following steps must be carried out by an ABB Turbocharging Service
Station:
 Checking the component
 Replacing the desiccant
 Repackaging the component
Replacement components which are ready for operation
If the 70% field of the hydrometer (2) has not changed colour and the pack-
age is not damaged, the replacement turbocharger or replacement cartridge
NOTICE
group can be put into operation without previously having been checked by
an ABB Turbocharging Service Station.
3.4

Intended use

Use on internal combustion engines
ABB turbochargers are intended for turbocharging internal combustion engines.
For use on gas engines, the enginebuilder must assure its end customers that, in compliance
with the Machinery Directive 2006/42/EC, the turbocharger will be operated in an engine room
that has the classification "not at risk of explosion". This is in accordance with the position pa-
per [2] relating to ATEX issued by EUROMOT [1].