ABB A140-H56 Operation Manual page 41

Turbocharger
Hide thumbs Also See for A140-H56:
Table of Contents

Advertisement

Operation Manual / A130-H.. - A140-H..
4
Removal and installation
4.4.6
Connecting the turbocharger
Connect cable to speed sensor (86515).
Connect all gas, air and oil pipes.
Version with water-cooled bearing casing
Remove the screw plugs on the water connections and fit the water pipes according to the
enginebuilder's specifications.
Version with compressor wheel cooling
Failure of compressor wheel cooling
Any prolonged failure of the compressor wheel cooling will shorten the re-
placement interval of the compressor wheel.
CAUTION
Ensure the supply of cooling air.
Figure 21
Remove the screw plug on the connection for the compressor wheel cooling (6) and fit the
cooling air line.
© Copyright 2013 ABB. All rights reserved.