Operation Manual / A130-H.. - A140-H..
5
Commissioning
5.2.3
Checks after commissioning (engine in idle mode)
Lubricating system
Check the oil pressure in the oil supply pipes.
Check oil inlet temperature.
The admissible values are specified in chapter Monitoring during operation [➙ 47].
Gas, air, water and oil pipes
After starting the engine, check all gas, air, water and oil pipes for leaks.
5.2.4
Checks when starting up the engine
Measure speed, oil pressure and charging pressure at various engine performances.
Measure the exhaust gas temperature before and after the turbine.
Measure the air temperature before and after the compressor.
The measured values must be compared with the values of the acceptance protocol; different
operating conditions must be taken into account here.
Escape of oily fluids
Lubricants and pastes used during assembly can liquefy or vaporise and es-
cape as oily fluids during the initial hours of operation. Continual escape of
NOTICE
an oily fluid indicates a possible oil leak.
If there is a leak, contact an ABB Turbocharging Service Station.
© Copyright 2013 ABB. All rights reserved.