Operation Manual / A130-H.. - A140-H..
11
Taking out of operation at short notice
11.4
Fitting the cover plate
Remove turbocharger (see chapter Removal and installation [➙ 29]).
Gas outlet casing removed
Fit the turbine casing with the gas outlet casing into the gas pipe again.
Attach the cover plate (see following section).
Gas outlet casing not removed
Fit the turbine casing into the gas pipe and on the gas outlet casing again.
Attach the cover plate (see following section).
Figure 48
Make sure that the oil connections in the bracket are equipped with gaskets.
Close the opening in the turbine casing (51000) with the cover plate (A).
Thoroughly clean the fastening strips (51002) before assembly. Coat the threads of the
studs (51006) with high-temperature grease.
Fasten the cover plate (A) on the turbine casing (51000) with fastening strips (51002), Ver-
busripp washers (51003) and nuts (51007) and screw it onto the bracket.