Operation Manual / A130-H.. - A140-H..
8
Periodic maintenance
Cleaning the absorption segments
(see Figure 25)
Loosen the tension bands (81270).
Remove the cover grid (81266).
Pull out and bend up the cover sheet-metal (81137), and remove the absorption segments
(81136).
Clean the absorption segments (81136).
When cleaning, note that the absorption segments (81136) must only be cleaned lightly
with pressurized air, with a soft brush or a moist cleaning cloth.
Have any heavily contaminated absorption segments replaced by an ABB Turbocharging
Service Station.
Fitting the filter silencer
(see Figure 25)
Insert the absorption segments (81136) into the cover sheet-metals (81137).
Bend the cover sheet-metals (81137) into the original shape and insert into the slotted gui-
des in the filter silencer body (81135).
Fit the cover grid (81266).
Fit the tension bands (81270) and tighten them at the locks (81271).
Any tension bands that have become damaged must be replaced.
Fit the filter ring (81265), if present.
© Copyright 2013 ABB. All rights reserved.
HZTL2414_EN
Page 70 / 115
Revision B
March 2013