7
Operation and service
7.2.1
Service procedures every 25 ... 50 hours
Visual control for air, exhaust gas, water, and oil leaks
Recording of operating data as well as entries in the engine logbook
In case of deviations, determine the cause.
Unknown operational changes
Impairment to the degree of a possible operating failure can be the conse-
quence.
CAUTION
Unknown causes must be clarified by an ABB Turbocharging Service Sta-
tion.
7.2.2
Service work at 100 hours after commissioning
Clean or replace the oil filter located in the supply pipe to the turbocharger while the engine
is stopped.
7.2.3
Service work according to instructions of enginebuilder
Clean or replace the oil filter located in the supply pipe to the turbocharger while the engine
is stopped.
7.2.4
Service work after 8000 ... 12000 hours of operation
Service work after 5 years the latest
After 5 years, engine damage can occur even though the specified operating
hours may not have been reached yet.
CAUTION
Carry out service work after 5 years the latest.
Shortened service intervals
Exceptional stresses (such as several starts/stops per day), harsh environ-
mental conditions or high system vibrations can lead to untimely engine da-
CAUTION
mage even if the prescribed service intervals were observed.
Agree on a shortened service interval with ABB Turbo Systems.