Operation Manual / A130-H.. - A140-H..
7
Operation and service
Fuel quality
Load profile (thermal cycling, also number of starts/stops, emergency shutdowns)
Gas inlet temperature
Frequency and execution of turbine and compressor cleaning
Turbocharger specification.
For bearing parts
Lubricating oil quality (oil filtering, oil condition, oil monitoring)
Load profile (speed, pressure conditions, temperature)
Imbalance of the rotor (degree of contamination)
7.4
Stopping the engine
Stopping the engine with water-cooled turbocharger model
The heat must be dissipated from the turbocharger.
CAUTION
Allow the water cooling of the turbocharger to continue for 15 to 20 minu-
tes after stopping the engine.
Stop oil lubrication immediately after stopping the engine. Post-lubrication
is neither required nor recommended.
Post-lubrication
Post-lubrication is not required and not recommended for water-cooled bearing casings.
For oil-cooled bearing casings, post-lubrication is mandatory for 15-20 minutes if the turbi-
ne inlet temperature (t
– 550 °C with insulated casing
– 600 °C with non-insulated casing
At temperatures below the specified values, post-lubrication for 10 minutes is recom-
mended.
Observe the oil pressure specified for post-lubrication (see Table 5).
© Copyright 2013 ABB. All rights reserved.
) exceeds the following values when the engine is stopped:
TE
HZTL2414_EN
Page 59 / 115
Revision B
March 2013