Operation Manual / A130-H.. - A140-H..
10
Disassembly and assembly
10.9
Axial clearance A and radial clearance B
Figure 45
After the removal and before the installation of the cartridge group, axial clearance A and
radial clearance B must be measured and recorded.
For correct measurement of axial clearance A, the turbine must be lifted slightly.
Axial and radial clearance [mm]
A
B
Table 33
Clearances outside the tolerance
Serious damage to engines or property can be caused by clearances outsi-
de the tolerance and excessively worn parts.
CAUTION
Have the components assessed and, if necessary, replaced by an ABB
Turbocharging Service Station.
© Copyright 2013 ABB. All rights reserved.
A130
0.08 ... 0.16
0.10 ... 0.18
0.47 ... 1.00
0.58 ... 1.16
A135
A140
0.12 ... 0.21
0.70 ... 1.37
HZTL2414_EN
Page 102 / 115
- -
- -
- -
Revision B
March 2013