4. Operation
Source and Destination Buttons
If a source button is illuminated, then a signal is present on that source. If a destination button is illuminated,
then a powered display is attached to this output (Hot Plug Detect signal is present).
INFO:

Keep in mind that I/O boards have different capabilities to sense signals and monitors, therefore
this function could be inadequate with certain I/O boards.
TIPS AND TRICKS:

You can quickly check the cable connections with this feature.
Signal on Test Input
This screen shows the actual incoming signal resolution on the Test input
port.
Press the up ▲ or down ▼ button to go to the previous or next screen.
Signal on Preview Output
This screen shows the actual signal resolution that presents on the
Preview output port.
Press the up ▲ or down ▼ button to go to the the previous or next screen.
Crosspoint Status
Navigate to the Crosspoint submenu item with the up ▲ and down
▼ buttons and then press the enter  or right ► button to step in this
submenu.
The crosspoint connections are shown. One screen shows connected
inputs for nine outputs. Further outputs can be checked by scrolling
through screens with the up ▲ and down ▼ buttons.
Every output's connection is shown like this: 'o01i03'. In this example, it means that input 3 is connected to
output 1.
Press the escape  button to return to the main Signal present menu.
MX-FR Series Modular Matrix Frames – User's Manual
4.10. Remote Operation
4.10.1. Control Interfaces
Signal present
Test input:
1600x1200p60
Signal present
Preview output:
no signal
Crosspoint status
o01i03 o02i12 o03i12
o04i12 o05i12 o06i12
o07i12 o08i12 o09i12
Applied CPU2 firmware: v3.5.7b8 | LDC software: v2.5.17b2
Lightware matrix routers can be controlled through various interfaces remotely. The feature allows functions
that are not accessible via the front panel and useful for system integrators and operators to control multiple
devices in a complicated system through a single user interface.
The user can connect to the matrix through
Ethernet (TCP/IP),
Serial port (RS-232 or RS-422),
USB (if available on the matrix frame front panel)
After establishing the connection, there is no difference between the connection types (except the RICOD
and some rare cases, which are uniquely noted).
The RICOD enables only switching inputs, locking and unlocking device's buttons.
The available remote connections and the relating chapters are listed below.
Connection Type
User Interface
Ethernet
RS-232
Port
Serial Port
Built-in website
-
ü
ü
Lightware Device
ü
ü
ü ü
Controller software
Third party control system
ü
ü
ü ü

ATTENTION!
Ethernet port can be connected to a LAN hub, switch or router with a UTP patch cable. If
connecting to a computer directly, a cross-link UTP cable has to be used!
Further Information
USB Port
-
Software Control - The Built-in Web
Software Control – Lightware Device
ü ü
Controller Software
-
Programmer's Reference
63