Available languages

Available languages

Layout of the software display
Messages
10.8.3

[General parameters] - [Unit Meter]

In [General parameters] - [Unit Meter] can be used to set how many units
(bottles or crates) per pulse are to be recorded.
Fig. 43: [General parameters] - [Unit Meter]
1
Setting the units per pulse for plant 1.
1.
In the „home screen"
use the
ð The overview: „Parameters: General" is displayed.
Ä Chapter 10.8.1 „[General parameters]" on page 73
2.
Press button [Unit counter] .
ð The overview: „Parameter: Units" is displayed.
10.9

[Messages]

The menu option [Messages] displays error messages.
Fig. 44: Messages
1.
In the „home screen"
use the
ð The overview: „error messages" is displayed.
2.
Press button [Signal buffer] .
ð The overview: „Signal buffer" is displayed.
Rev. 02-09.2017
Ä Chapter 10.3 „ „home screen" (start screen)" on page 54
button to switch to the general parameters.
Ä Chapter 10.3 „ „home screen" (start screen)" on page 54
button to switch to the view of the [error messages] .
This overview only displays active, unacknowledged error messages.
This overview displays ALL error messages ever recorded by the
system, including those already displayed and the open messages.
76
2
Setting the units per pulse for plant 2.