10.4.5.3 „System settings" [Signals] [Digital Outputs]
Monitoring of the outputs (not signal exchange) coming from the control for commissioning
and maintenance purposes.
Fig. 21: „System settings" [Signals] [Digital Outputs]
1
Button to exit the menu. The screen switches to
the „home screen" .
2
Set active time: Activation time if [Start] (Pos.3) has
been pressed meaning the button is on [Stop] will apply
the activation time.
1.
button [Signals] Press to open the signal settings.
ð The overview: „Manual activation / signal exchange" is displayed.
2.
Press button [Digital Outputs] .
ð The selection: „Man. actuation / digital outputs" is displayed.
3.
Press button [Output byte AB 0/1] .
ð The selection: „Man. Actuation AB 0/1" is displayed.
4.
Press button [STOP all] .
ð Stop all set outputs. [Start] Buttons change [Stop] buttons.
5.
Press button [Output byte AB 2/3] .
ð The selection: „Man. Actuation AB 2/3" is displayed.
6.
Press button [STOP all] .
ð Stop all set outputs. [Start] Buttons change [Stop] buttons.
Layout of the software display
System settings > Overview: System settings Signals
3
Switching the activation time on and off ([Start] = red
button, [Stop] = white button.
4
System button to exit the menu.
61
Rev. 02-09.2017