5.7  Specifications
8
5
DIN_1-
7
DIN_2-
Key
Meaning
A Digital Input Circuit C DOOR_IN1
B SAFE_5V
Outputs
NO relay with voltage-free contacts
l
Contact rating 30 VDC, 2 A max (resistive)
l
Supports 2 inputs and 2 outputs
l
These have preset behavior for call buttons, which cannot be changed. The outputs can
be used for a beeper, light, or other use. Both inputs act as external push-button presses.
NOTE: A call button can be turned into a door box with the DIP switch,
in which case the I/O can be configured by the user.
When used as a door box, Output1 is dedicated as a signal to the door actuator to open
the door. Only Output2 is available to the user.
Call Button ON when
Door Box
I/O Box
Inputs and outputs are configured in the MobilePlanner software.
l
See Configuring External I/O on page 76 and Configuring an Output Signal on page 74.
84
B
6
&
R
R
A
Figure 5-30 Input Circuit Schematic
Key Meaning
D DOOR_IN2
Output1
In Progress
Door
user
LD Platform Peripherals Guide
R
0.10A
VCC
GND
Output2
Input1 Input2
ON for ≥ 1 second
Button
after Arrival
press
user
user
user
user
V5
C
D
Button
Press
user
user
13732-000 Rev J