4.1  Installation
4x
M4 x 8 (0.31)
4x M4
Figure 4-3 Standoffs/Spacers for Mounting the Touchscreen (Welded Shown) (units are mm (inches))
Key
Meaning
A
Top View
B
Mounting Screws
C
Standoff
D
Threaded Standoff on Inside of
Panel
1. Install the gasket between the touchscreen and the inside of the payload structure sur-
face.
Line up the gasket with the hole in the payload structure surface, so the gasket aligns
with the screen cutout.
2. Attach the touchscreen to the inside surface of the payload structure.
If the mounting standoffs are welded to the inside of the payload structure, use four M4
x 8 mm (0.31 in.) screws to attach the touchscreen bracket. Use a threadlocker, such as
Loctite 222.
If you are using thru holes, you will have to determine the length of bolt needed to go
through the mounting surface, spacer, bracket, and into the nut. Use either nylock nuts
32
B
7.17
(0.282)
C
82
(3.23)
D
E
40.61
(1.599)
44.39
(1.748)
105.86
(4.168)
Key
E
Optional Through Hole for Mounting from the
Front
F
Thick Foam Tape Gasket around Inside of Panel
Opening
G
Recommended Touchscreen Mounting
H
Front View
LD Platform Peripherals Guide
A
164
(6.46)
82
(3.23)
109.14
(4.297)
H
G
Meaning
0.76 (0.03)
F
48
(1.89)
96
(3.78)
48
(1.89)
13732-000 Rev J