Chapter 6. Troubleshooting
6.1 Flowchart to Remedy the Troubles
Figure 6.1 shows the flowchart to remedy the troubles from when power to the emulator is activated
until the emulator debugger starts up. Check this while the target system is disconnected.
For the latest FAQs, visit the Renesas Tools Homepage.
Figure 6.1 Flowchart to remedy troubles
Turning on the power of PC4701
Front panel LED of
PC4701
Init dialog box of emulator
debugger displayed
Program window of emulator debugger displayed
http://www.renesas.com/en/tools
LED not normal
1. Check emulator system connections.
See, "3.6 Connecting the PC4701" (page 41).
2. Redownload the firmware.
See "4.2 Downloading Firmware" (page 48).
3. Restart the PC4701 system.
Not normal/Error displayed
1. Check the operating environment etc. of the emulator
debugger.
See the user's manual of the emulator debugger.
2. Reinstall the emulator debugger.
Error displayed
See "6.2 (2) Errors Occur When the Emulator Debugger Starts
Up (When the target system is connected) (page 68).
See "6.2 (3) Errors Occur When the Emulator Debugger Starts
Up (When the target system is not connected) (page 69).
( 66 / 76 )