Selecting Clock Supply - Renesas Emulation Pod M306H2T-RPD-E User Manual

Emulation pod for m16c/6h group m306h2
Table of Contents

Advertisement

3.3 Selecting Clock Supply

There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.5 lists the factory-settings of each clock
supply.
Table 3.5 Clock supply to the MCU
Clock
X
IN
X
CIN
Notes on Changing the Clock Supply:
Description
Internal oscillator circuit of emulation pod
(OSC-3: 10 MHz)
-X
OUT
Target system
Internal oscillator circuit of emulation pod
(OSC-2: 32.768 kHz)
-X
COUT
Target system
• The clock supply can be set by the Init dialog box when starting up the emulator
debugger or inputting CLK command on the script window.
• For X
-X
CIN
COUT
to "3.2 Setting Switches and Pullup Resistors" (page 29).
Display of emulator debugger Default setting
IMPORTANT
, it is necessary to set switches in the emulation pod. For details, refer
( 35 / 76 )
Internal
External
Internal
External
Yes
-
Yes
-

Advertisement